Nitrex

Nitrex Extra Sensitive Blue Nitrile Powder Free Gloves

GN01
    Unit of issue:
  • Case (10 x 200 Gloves)
  • MDR - Class I - PPE CAT III
  • MD Class 1
  • UKCA
  • EN 374-1:2016 Type B

    KPT

  • EN 374-5:2016

    VIRUS

  • AQL 1.5
  • Single Use Only
  • information
Beaded Cuff:
  • Beaded cuff to aid donning
Grip:
  • Textured fingertips provide an improved grip and optimise surface performance in both wet and dry conditions
Latex Free:
  • Latex Free reducing the risk of hypersensitivity and allergic reactions
Powder Free:
  • Reduced risk of dust contamination
Suitability:
  • Suitable for use with cytotoxic/chemotherapy drugs
Disposable Gloves Standards:
  • AQL 1.5
  • Compliant with European Standards EN455: Medical Gloves for Single Use parts 1,2,3&4
  • EU Certified
  • Manufactured in accordance with Personal Protective Equipment (PPE) by the European PPE Regulation (EU) 2016/425
  • Tested to European standards EN ISO 21420, EN ISO 374-1, EN ISO 374-4 & EN ISO 374-5
  • This product is classified as Class I Medical Device in compliance with the requirements of Medical Device Regulation (EU) 2017/745 & UK MDR 2002 (SI2002 No.618 as amended) (UKCA)

NITREX Extra Sensitive examination gloves are manufactured from a high quality nitrile formulation resulting in a strong performing glove with a high level of tactile sensitivity. The advanced thin film technology utilised in the manufacture process results in a glove, which provides outstanding barrier protection against viruses, bacteria, chemicals and has been tested for permeation performance against 13 chemotherapy drugs.

Product Colour: Blue
Packing: 200 gloves per dispenser / 10 dispensers per case
Size Range: XS-XL
Fingertip Thickness: 0.06 mm
Palm Thickness: 0.05 mm
Typical Weight: 3 g
Icon Label Type Size Download
pdf Nitrex Extra Sensitive Blue Nitrile Gloves CE Conformity Statement pdf 250.3 KB Download
pdf GN01 Nitrex Extra Sensitive Blue Nitrile Powder Free Gloves Data Sheet - en-GB pdf 1.2 MB Download

   Frequently Asked Questions and Answers


   Ask a question

Terms & Conditions

There is no content for Term & Conditions.
I Agree with the Terms
Contains accelerator chemicals which may cause type IV skin irritation and contact dermatitis in sensitised individuals.
Weight does not form part of the specification and is subject to change. Palm thicknesses is approximate and based on an agreed manufacturing tolerance. All thickness and weights given are an average for medium (8) gloves. All thicknesses and weights given are correct to the best of Polyco Healthline Ltd.’s knowledge at the time of input, however due to the manufacturing process, both thickness and weight may vary between batches.